Reusable anchor for fall protection for 1 individual that can be shaped to meet up to a 12/12 roof pitch or can be used on flat decking over rafters.
| Phase of Construction |
| Roof truss installation, roof sheathing, siding installation, HVAC, maintenance |
| Manufacturer’s Device Page |
| Super Anchor |
| Installation |
| Install over flat or sloped sheathing placed directly over and in line with the rafter or directly onto rafter if at the ridge. Drive ten 12# 2 7/8" hex drive screws into the center of the rafter using supplied hex driver attachment for drill. Special installation instructions must be followed if using inverting in attics. Warning: Users must strictly adhere to the manufacturer’s inspection, installation, maintenance and use directions; and must follow local, state and federal safety regulations. Structural member must be able to support 5000# force. Failure to do so could result in serious injury or death. |
| Manual |
| Instruction Manual |
| Vendor |
| Super Anchor, peaksupplycompany.com, fallprotectionsolutionsllc.com, ordexsupply.com |
| Cost |
| $15-62 |