Purpose

Roof mounted self-contained retractable lifeline that provides mobility for 1 worker (310# maximum). Can be used on wood
sheathing (RM55-4) or metal structural members and metal sheathing (SRMF-2). Must be used with Miller fall protection approved components.

Phase of Construction
Roof sheathing, floor sheathing, roof shingling, wall installation
Manufacturer’s Device Page
Miller Fall Protection/Honeywell
Installation
Structure must be capable of supporting 5,000# or maintain a safety factor of at least 2. Should be installed at least 6’ feet from any roof edge, with bracket straddling the peak evenly at center of roof. Sites that reduce the potential for swing fall hazards are preferred. Install three (3) 16d nails with complete heads into each foot plate fully through the sheathing and into the roof's structural member. On metal structures (4) four screws are installed into 1/4" outer most holes, screws must pass through the sheathing and into metal structural member. Warning: Users must strictly adhere to the manufacturer’s inspection, installation, maintenance and use directions; and must follow local, state and federal safety regulations. Structural member must be able to support 5000# force. Failure to do so could result in serious injury or death.
Manual
Instruction Manual
Vendor
bosssafety.com, 365-safety.com, airgas.com
Cost
$1350.55 - $1919.77

 

 

Roofstrider System

Roofstrider System

Roofstrider System

Roofstrider System